IG051514-1.0
1.877.817.6028
www.DiodeLED.com
INSTALLATION GUIDE
®
1 OF 3
RGB WALL MOUNT COLOR CONTROLLER
• Install in accordance with the Naonal Electric Code, and local
regulaons.
• This product is intended to be installed and serviced by a qualied,
licensed electrician.
• Do not connect directly to high voltage 120V~277V power. Install with
a compable Class 2 constant voltage LED driver (power supply).
• Only install compable LED drivers and xtures. Contact technical
support or visit the product page for compable products.
• This product is rated for indoor installaon and is not protected against
moisture.
• Proper heat dissipaon will prolong the working lifespan of this product.
Install in a well-venlated area free from explosive gases and vapors.
• Ensure applicable wire is installed between driver, xture, and any
controls in between. When choosing wire, factor in voltage drop,
amperage rang, and type (in-wall rated, wet locaon rated, etc.).
Inadequate wire installaon could overhead wires, and cause a re.
• Do not modify or disassemble this product beyond instrucons or the
warranty will be void.
Safety & Warnings
Prior to installaon, verify all components are a compable system. Congure and pre-test your LED system prior to permanent installaon to ensure all
components are operang correctly. Install in accordance with the NEC and local regulaons.
Installation
Quick Specs
Ambient Temperature † -4° ~ 122°F (-20° ~ 50°C)
Transming Distance 130 .
Control Type
Pulse Width Modulaon (PWM).
3-channel RGB xtures.
Input / Output Voltage 12-24VDC constant voltage
Max Current Load 3A x 3CH Max 9A
Max Output Power
108W/216W (12V/24V)
Environment Indoor / dry locaon
† Do not install product in an environment outside the listed ambient
temperature.
Turn OFF High Voltage AC Power at the main breaker.
Determine Locaons to Install 3 Main Components.
Refer to the ‘System Diagrams.’
Mount RGB Receiver to Surface. See ‘Wiring Connecons’, use
applicable screws.
Aach Lighng Load and Driver. Only use copper wiring.
Reference ‘Wiring Connecons’ located further in guide for
visual. Use a mini athead screwdriver for aaching wires to
terminal ports. Terminals t up to 12AWG solid-core copper wire.
Verify a compable constant voltage driver is installed.
Install Addional Components, Verify Connecons, and Turn
Main Power ON at Breaker.
ON
OFFOFFOFF
ONON
OFFOFF
ONON
1) Driver 2) RGB Color
Controller
3) Fixture
Ensure applicable wire is installed between driver, xture, and any
controls in between. When choosing wire, factor in voltage drop,
amperage rang, and type (in-wall rated, wet locaon rated, etc.).
ON
OFFOFFOFF
ONON
OFFOFF
ONON
If system remains unresponsive or is working improperly, turn OFF
main power at breaker and verify all connecons. Review the ‘Wiring
Connecons.’
DO NOT CONNECT DIRECTLY TO HIGH VOLTAGE POWER!
Read all warnings and installaon instrucons thoroughly.
WARNING
WARNING
Shock Hazard. May result in serious injury or death.
DO NOT CONNECT
TO HIGH VOLTAGE
Comentarios a estos manuales