1.877.817.6028
www.DiodeLED.com
INSTALLATION GUIDE
1 OF 4
RGB ZONE COLOR CONTROLLER
®
• Install in accordance with the Naonal Electric Code, and local
regulaons.
• This product is intended to be installed and serviced by a qualied,
licensed electrician.
• DO NOT connect directly to high voltage power. Install with a compable
Class 2 constant voltage LED driver (power supply).
• Only install compable LED drivers and xtures. Contact technical
support or visit the product page for compable products.
• This product is rated for indoor installaon and is not protected against
moisture.
• Proper heat dissipaon will prolong the working lifespan of this product.
Install in a well-venlated area free from explosive gases and vapors.
• Ensure applicable wire is installed between driver, xture, and any
controls in between. When choosing wire, factor in voltage drop,
amperage rang, and type (in-wall rated, wet locaon rated, etc.).
Inadequate wire installaon could overhead wires, and cause a re.
• Do not modify or disassemble this product beyond instrucons or the
warranty will be void.
Safety & Warnings
Prior to installaon, verify all components are a compable system. Congure and pre-test your LED system prior to permanent installaon to ensure all
components are operang correctly. Install in accordance with the NEC and local regulaons.
Installation
Quick Specs
Input / Output Voltage 5-24VDC constant voltage
Max Current Load 5A x 4CH Max 20A
Max Output Power
100W/240W/480W (5V/12V/24V)
Ambient Temperature
-22° ~ 131°F (-30° ~ 55°C)
Environment Indoor / dry locaon
Input Voltage 5VDC Built-in Lithium Baery
Transming Distance 90 .
Control Type
Pulse Width Modulaon (PWM)
3-channel RGB xtures
Ambient Temperature † -4° ~ 131°F (-20° ~ 55°C)
Turn OFF High Voltage AC Power at the main breaker. Determine Locaons to Install 3 Main Components.
Refer to the ‘System Diagrams.’
ON
OFFOFFOFF
ONON
OFFOFF
ONON
V+
V-
V+
B
G
R
1) Driver 2) RGB Color
Controller
3) Fixture
Ensure applicable wire is installed between driver, xture, and any
controls in between. When choosing wire, factor in voltage drop,
amperage rang, and type (in-wall rated, wet locaon rated, etc.).
DO NOT CONNECT DIRECTLY TO HIGH VOLTAGE POWER!
Read all warnings and installaon instrucons thoroughly.
WARNING
WARNING
Shock Hazard. May result in serious injury or death.
DO NOT CONNECT
RGB Zone Remote RGB Zone Receiver
For full specicaons, see the ‘Specicaon Sheet’ available at the online
product page.
†
Do not install product in an environment outside the listed ambient
temperature. Ensure adequate airow and heatsinking is considered
when mounng/installing.
DC+
DC-
V+
B
G
R
RF
RF
DO NOT PAIR MULTIPLE
REMOTES TO A SINGLE RECEIVER.
Zone 1Zone 1
DC+
DC-
V+
B
G
R
DC+
DC-
V+
B
G
R
RF
DO NOT SET MULTIPLE
RECEIVERS TO THE SAME ZONE.
IG060914-1.2
# DI-1700
# DI-1701